We received a customer report about a server slowdown on large volumes after the UB64 upgrade. In this case the deskserver process had used almost 100% of CPU when the slowdown occurred.
We investigated the issue and found that the customer had not performed the recommended desktop rebuild after migrating to UB64, as stated in the “Migrating HELIOS UB2 to UB64” notes.
We strongly recommend performing a desktop rebuild on all volumes after upgrading to UB64. This can be done either in HELIOS Admin:
=> Select the Volumes
tab.
=> Highlight the desired HELIOS volume.
=> Choose Rebuild Desktop
from the Volume
menu.
or by using the “rebuild” tool on a command line:
/usr/local/helios/sbin/rebuild -f VOLUMEPATH
The deskcheck.pl script gives an overview about the status of each configured volume.
Important: The script must be called as root!
Example:
$ perl deskcheck.pl
Checking databases ... done.
"/usr/local/helios/public"
"/usr/local/helios/var/ICC-Profiles"
"/usr/local/helios/var/settings"
"/Volumes/DATA/demovol"
or using the rebuild calls below:
Professioneller Support sowie erstklassige technische Informationen sind uns sehr wichtig. Dabei ist der HELIOS Fachhändler Ihr direkter Ansprechpartner. Unser Ziel ist es, alle Fragen zu beantworten und alle Probleme zu lösen.
Halten Sie Ihre HELIOS Installation immer auf einem aktuellen Stand – mit wichtigen Updates und Tech Infos zu verschiedenen Themen.
HELIOS Lösungen werden häufig in benutzdefinierte Prozesse integriert. Hier finden Sie weiterführende technische Informationen.
Die gesamte HELIOS Produktdokumentation ist online verfügbar. Eine breite Übersicht sowie viele verschiedene Trainingsvideos machen Ihnen der Einstieg leicht.
Aktuelle Version: G8/CD027 • Letztes Update: u1320 • Letzte Tech Info: Tech Info 207
Im Bereich HELIOS News finden Sie …
Letzter Pressetext: > HELIOS Universal File Server G8 veröffentlicht … • Letzter Newsletter: > HELIOS Newsletter 02/2021 …
© HELIOS Software GmbH. Alle Rechte vorbehalten.